Add to Cart
STS Prepaid Electricity Meters For Indonesia , Tamper Proof Single Phase KWH Meter
The CA168-I is exclusively designed and manufactured for Indonesian market. It is the lowest cost and cheapest STS keypad prepayment meter .It has full function features of STS prepaid meters, keypad based, 20 digits' encrypted codes, tamper detection, power limit setting and class 1s metrology accuracy.
It is a compact and keypad-based design in a BS8565 standard housing and maintains IP54 rating, allowing it to operate in harsh environments. The meter is supplied to Indonesian local market and serve as a secured utility dispenser with enhanced revenue protection features.
CA168 Single -phase Prepaid Electricity Meter provides acompact solution for energy measurement and prepayment. Credit dispensing. The management data is transferred from a point of sales (POS) to the meter via a 20-digit numeric token that is generated using the Standard Transfer Specification (STS) encryption protocol. The voucher number is entered into the meter via a keypad.
CA168 is an upgrade of highly successful CA range Single Phase keypad electricity meter. It is tailored to meet the international demand for STS protocol. Feedback received from customers for CA range over the last 10 years has been reflected on the design of the meter, making CA168 a reliable and robust product that exceeds customer requirements and expectations.
Features
1) Significant reverse energy measurement SRE
2) IEC62056-21 compliant optical & RS485 comm port for data transfer
3) Prepayment and credit mode
4) Disconnects on overload and no credit
5) Programmable power limit and low credit warning level adjustable
6) Tamper proof against opening cover, reverse connection, black-out and etc.
Specifications:
Nominal voltage Un |
220/230/240 V |
Limited voltage |
70%~120%Un |
Nominal frequency fn |
50-60Hz+5% |
Basic current(Ib) |
5-10A |
Maximum current(Imax) |
60-100A |
Starting current(Ist) |
20mA |
Active energy constant |
1000imp/kWh |
Accuracy as Active energy to IEC62053‐21 |
Class1.0 |
Power consumption in Voltage circuit |
<2W <8VA |
Power consumption in current circuit |
<1VA |
Operating temperature |
25℃ to+70℃ |
Storage temperature |
40℃ to+85℃ |
Insulation level |
4kV rms for 1min |
Impulse voltage withstand |
8kV, 1.2/50 μs |
Air discharge |
16kV |
Immunity to HF fields |
|
80MHz to 2GHz with load |
10V/m |
100kHz to 1GHz without load |
30V/m |
Fast transient burst test |
4kV |
Meter shell Protection Rate |
IP54(IEC60529) |
Insulation System Classification |
Protective Class II |